The outdoor and indoor units of your HVAC system have to be constantly communicating, in order to keep your house at a comfortable temperature. If there is a communication fault, the system won’t be able to operate effectively.
In a Carrier unit, code 179 indicates an outdoor unit communication fault; an issue with the wiring anywhere in the system can cause such an error. To find out the root cause of the problem, you would have to check the communication wires and the float switch.
You are watching: Carrier Outdoor Unit Communication Fault – Troubleshooting Guide
Carrier furnaces have lights that will start blinking if an error ever occurs. Each fault code is a two-digit number.
To find out the digits, pay attention to the short and long flashes (the short flashes determine the first number and the long ones – the second). For example, one short flash and three long flashes correspond to error code 1-3 – ‘limit or flame roll-out switch lockout’.
Read: Why Carrier Thermostat Blinking Cool ON? – Troubleshooting Guide
Fault code 24 indicates that the secondary voltage fuse is open. You would have to replace either the fuse or the control board.
It looks like the sensor had gone bad and it is no longer recognized by the circuit board. To fix the issue, you would have to install a new sensor.
Such a fault code can appear if the system is overheating. Make sure that the supply and return grills are not blocked, that the air filter is not clogged, and that the ducts are clean.
If the error does not go away, then there might be an issue with the gas valve and the manifold pressure. In such a case, it is better to call a professional.
Read: Carrier Furnace Error Codes – Troubleshooting Guide
Error code 13 means ‘limit circuit lockout’ – the flame or roll-out switch has been open for over 3 minutes. Check if the system has proper airflow and make sure that the actual switch is not faulty.
A loose or damaged wire anywhere in the system can cause an ‘outdoor unit communication’ fault. Basically, even when the system displays that the connection has been lost with the outdoor unit, the actual loss might have happened either inside or outside.
Read more : Issue: Decem1er 1, 2001
You would have to change the wiring for the communication wire.
First things first, make sure that you have power to the outdoor unit. If this part of the system is not receiving any power, then it will not register.
Also, do check the outdoor circuit board – there shouldn’t be any blown fuses or tripped breakers.
If the code appears on your Carrier Infinity thermostat, then you should:
An indoor unit communication fault does not necessarily mean that the problem is with the indoor unit. You might have to check the entire system.
Read: Why Furnace Is Making A Clicking Noise – Troubleshooting Guide
On a Carrier unit, ‘system malfunction’ can mean a wide range of things. You can press and hold the right-side button for a few seconds – the thermostat will display any current errors that the system is experiencing, this will help you get a better understanding of the problem.
If you need the heating and cooling unit to start operating, then you can dismiss the ‘system malfunction’ message. Simply press the right-side button and the message will appear where the date/time should be.
You can also try resetting the system.
Do bear in mind that calling an HVAC expert that would take care of the problem is the best possible decision.
You can enter the diagnostic mode on your thermostat:
Read: Best Furnace Flame Sensors
Read more : Mealybugs – outdoors
All stored status codes are going to be erased as soon as the power to the system is interrupted. So, you can simply reset the unit.
The reset button is usually located right on the control panel. The button can be quite small, but you should be able to find it thanks to a special label.
At times, you might have to search beneath the digital display to locate the button.
You’ll find the red reset button right in the middle of the flame roll-out switch. This switch is usually located on the top or the side of the burner compartment.
You can temporarily override the scheduled cooling temperature settings and then return to the scheduled program.
The majority of new furnaces, including gas units, have a fuse as the system requires an electrical connection to operate. Fuses protect the unit from a potential overload or short.
The exact location of the fuse will depend on the model of your furnace. Usually, the element can be found in the furnace housing unit.
Open the furnace access door – there, you will find the circuit board and, most likely, the fuse. These elements are often small, colored, and made out of plastic.
Read: No Power To The Home Temperature Thermostat – Troubleshooting Guide
Error code 24 on your Carrier furnace means that the secondary voltage fuse is open. All transformers are actually connected to the common secondary circuit via a secondary fuse (it is placed after the transformer’s output points of connection on the secondary side).
In most cases, you would have to remove the service door on the indoor unit and locate the circuit board. The fuse should be plugged right into the board (it might look like a car-type, purple fuse).
If you replace the fuse with a new one and it blows as well, then your system has a short.
Source: https://gardencourte.com
Categories: Outdoor
For all my beauties with dark inner thighs, armpits, bikini area and spots, etc, this…
Are you a passionate cook aspiring to embark on a rewarding culinary journey? Whether you're…
Discover the perfect wall colors to complement your grey kitchen cabinets, creating a harmonious and…
Generally, a 10×10 kitchen remodel ranges from $15,000 to $45,000, but several factors could cause…
Sleek and durable, quartz countertops are the latest trend in kitchen and bathroom renovation. Comparable…
IKEA kitchens are designed to be as simple as possible to assemble and install yourself.…